ServiceManualEF472
25
R E P A I R S
Repairtipsforpump
• Alwaysreplaceadefectivepump(48)togetherwiththefinewirefuse.
• Wheninstallinganewpumptheangledhoseconnection(44)mayhavetobe
realigned:thewhiteplasticIidonthepumpisrotatableandhastwoflatsurfaces
ontowhichtheflatwrenchcanbeplaced.
Mounting tipforthethermoblock
• Whenmountingthethermoblock(5)alignthepositioningholesonthebottomtothe
dampingelement(8).
Check for water
leaking from the
pump.