T R O U B L E S H O O T I N G
4 T R O U B L E S H O O T I N G
4.1 Checklist
With an acceptance
check in accord-
ance with this checklist,
errors are quickly found
and corrected with the
appropriate measure.
Therefore, adhere to the
sequence of the check
list.
Repair every occurring
error and work the check
list until it is completed.
Check Errorsymptoms
Measure/
repairwork
Furthermeasures/repair
work
1Checkthecoffee
machineforvisi
bledamage
1.1Housingpartsbro
kenordamaged
YESreplacehousingpartsif
necessary
NOcontinuewithpoint1.2
1.2Mainscabledam
aged
YESreplacethemainscable
NOconnectthecablefrom
machinetothemainsandcon
tinuewithpoint2.1
2Checkmechani
calcomponents
2.1Whenthecoffee
machineis
switchedoff,the
cuptrayremainsin
theverticalposition
YEScontinuewithpoint2.2
NOcheckifthecapsulecon
tainerandthecuptrayarecor
rectlyinsertedandmounted
YESreplacedamagedor
deformedcuptray
2.2Closinghandle
functions
YEScontinuewithpoint2.3
NOitisverydifficultoralmost
impossibletoclosethehandle
andtopressitallthewaydown
YESreplacethecompact
brewingunit
2.3Thecapsuleis
ejectedcorrectly
YEScontinuewithpoint2.4
NOreplacecompactbrewing
unit
2.4Sealonthecapsule
cageisdamaged
(checksealwith
yourfinger)
YESreplacethecompact
brewingunit
NOcontinuewithpoint3
3Fillwatertank 3.1Watertankleaks
YESreplacewatertank
NOcontinuewithpoint4
4ActivatetheOn
Offswitchtoper
formtheauto
maticselftest.
4.1Cuptrayfoldsdown
YEScontinuewithpoint4.2
NOlockingmechanismworksYESreplacedamagedor
deformedcuptray
NOreplacelockingmecha
nism
4.2Thecoffeemachine
isnotworking
(doesnotfunction)
YESa)mainscableisokay YEScontinuewithpointb)
NOreplacemainscable
YESb)onoffswitchisokay YEScontinuewithpointc)
NOreplaceonoffswitch
YESc)pumpworks(pressa
coffeebutton)
YEScontinuewithpointf)
NOcontinuewithpointd)
YESd)bothcoffeebuttons
areworking
YEScontinuewithpointe)
NOreplacetheentireelec
tronics
YESe)finewirefuse(128°C)
onthepumpisdefective
YESreplacefinewirefuse
NOreplacepump
YESf)finewirefuse(s)
(167°C)onthethermoblock
defective
YESreplaceentire
electronics,ifnecessary,even
replacethermoblock
NOcontinuewithpointg)