F U N C T I O N T E S T S
6 F U N C T I O N T E S T S
6.1 Measurefl owrate
1) Fillthewatertank.
2) Pushtheconnectoradapterintothe
capsulebay.
3) Carefullyclosethehandle,untilthe
adaptersitsfirmlyinthecapsulecage.
4) Pulloutthemount.Theadapterlocks
withthecapsulecage.
5) Placeameasuringcupunderthedrain
hoseofthepressuretester.
6) Switchonthecoffeemachine.
7) Afterheatingup,pressthe"Smallcup"
button.
8) Openthevalveuntilwaterbeginsto
flow.
9) Closethevalveuntilthepressure
gaugeindicates12bar.
Constantlymonitorthepressure
gaugeandifrequiredreadjustthe
valve.Asthetemperature
increases,sodoesthepressure,
readjustthepressureto12bar
whenrequired.
10) Carryoutmeasurementforapprox.30
sec.
11) Atleast60120 mlofwatermustbein
themeasuringcup.
Notices:
• Should<60mlleakout,thenthepump
isdefectiveorthereisaleakinthe
watersystem.
• Largedeviationsinindicatedpressure
whilemeasuring(±4bar)meansthat
thepumpisdefective.