3 Transport/Temporary Storage/Disposal
12 of 68
Calio
1157.821/04-EN
3.2.1 Placing the pump set down
WARNING
Insufficient stability
Risk of crushing hands and feet!
During assembly/dismantling, secure the pump (set)/pump parts to prevent
tilting or tipping over.
Place the pump set down as illustrated.
Fig.3: Placing the pump set down safely
3.3 Storage/preservation
CAUTION
Damage during storage due to humidity, dirt or vermin
Corrosion/contamination of the pump (set)!
For outdoor storage cover the pump (set) or the packaged pump (set) and
accessories with waterproof material.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump!
Clean and cover pump openings and connections as required prior to putting
the pump into storage.
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken :
Store the pump (set) in a dry, protected room at constant atmospheric humidity.
If properly stored indoors, the equipment is protected for a maximum of 12months.
New pumps/pump sets are supplied by our factory duly prepared for storage.
For storing a pump (set) which has been operated, observe the instructions in
(ðSection6.3.2,Page36) .
Table4: Ambient conditions for storage
Ambient condition Value
Relative humidity 80% maximum
Ambient temperature 0°C to +40°C
Well-ventilated
Dry
Dust-free
Shock-free
Vibration-free