6.1.9 Heating up/keeping warm the pump (set)
CAUTION
Pump blockage
Damage to the pump!
Prior to pump start-up, heat up the pump as described in the manual.
Observe the following when heating up the pump (set) and keeping it warm:
Make sure that the temperature is increased continuously.
Max. heating speed: 10 °C/min (10 K/min)
When the pump is used for handling fluids at temperatures above 150 °C make sure
that the pump has been heated throughout before starting it up.
The temperature difference between the pump's surface and the fluid handled must
not exceed 100 °C (100 K) when the pump is started up.
6.1.10 Start-up
DANGER
Non-compliance with the permissible pressure and temperature limits if the pump is
operated with the suction and/or discharge line closed.
Explosion hazard!
Leakage of hot or toxic fluids!
Never operate the pump with the shut-off elements in the suction line and/or
discharge line closed.
Only start up the pump set with the discharge-side shut-off element slightly or
fully open.
DANGER
Excessive temperatures due to dry running or excessive gas content in the fluid
handled
Explosion hazard!
Damage to the pump set!
Never operate the pump set without liquid fill.
Prime the pump as per operating instructions. (Section 6.1.4 Page 35)
Always operate the pump within the permissible operating range.
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
Switch off the pump (set) immediately.
Eliminate the causes before returning the pump set to service.
The system piping has been cleaned.
The pump, suction line and, if applicable, inlet tank have been vented and
primed with the fluid to be handled.
The lines for priming and venting have been closed.
CAUTION
Start-up against open discharge line
Motor overload!
Make sure the motor has sufficient power reserves.
Use a soft starter.
Use speed control.
Fluid temperatures above
150 °C
Temperature difference
6 Commissioning/Start-up/Shutdown