71PERIODIC SERVICE
ENGLISH
BBleeding Fuel System
Air must be removed:
1. When the fuel filter or lines are removed.
2. When tank is completely empty.
3. After the machine has not been used for a long period
of time.
C Bleeding procedure is as follows:
1. Fill the fuel tank with fuel.
2. Start the engine and run for about 30 seconds, and
then stop the engine.