EasyManua.ls Logo

Kubota WSM OC95-E2 - Check Point of Every 1 Year; Check Point of Every 2 Years

Kubota WSM OC95-E2
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OC60-E2, OC95-E2, WSM GENERAL
G-10
Nozzle Spraying Condition
1. Check the nozzle spray condition.
2. If the spray pattern and spraying direction are faulty, replace
the nozzle piece.
[7] CHECK POINT OF EVERY 1 YEAR
Cleaning and Changing Air Cleaner Element
A
Change air cleaner element (1) once a year or six times of
cleaning.
(Cleaning Air Filter Element)
A
When dry dust adheres
1. To clean the element, use clean dry compressed air on the
inside of the element.
Air pressure at the nozzle must not exceed 205 kPa (2.1
, 30 psi).
Maintain reasonable distance between the nozzle and the
filter.
[8] CHECK POINT OF EVERY 2 YEARS
Checking Fuel Hose and Clamp Bands
1. If the clamps (1) are loose, replace with new ones.
2. The fuel and lubricating hoses are made of rubber and ages
regardless of period of service. Change the fuel pipes
together with the clamps every two year.
3. However, if the fuel and lubricating hose and clamp are found
to be damaged or deteriorated earlier than two years, replace
with new ones.
(a) Good (b) Bad
0000009212E
(1) Element
0000009368E
(1) Clamp
0000009344E

Table of Contents