5.4 Operating time limit
Each cooking zone has its own operating time limit. This depends on the cooking level set and is
reloaded each time the level is changed.
Once the operating time limit is reached, the corresponding cooking zone is switched off.
The values are defined together for all 4 cooking zones as constants.
5.5 Power failure
The control can bridge a mains power failure of 1 second by switching off almost all power-consuming
components. This means that the starting condition of the hob can be reinstated if the power failure time
is less than 1 second. Reset then takes place on the microcontroller, i.e. the control initialises itself again
and all the user settings are lost. During this initialisation period E-00 appears in the actuator displays.
After initialisation of the control, the key-lock function is active when the appliance is first switched on
again.
Cooking zone Operating time limit
Code [Hours]
110
210
35
44
53
63
72
82
91
P1