Page #14 background imageLoading...
Page #14 background image
12 | 38
Atom series - v160120
Kvant Lasers s.r.o.
EN
Multiple System
Interlock
2.7
Multiple laser projectors may be daisy chained
and controlled by a single E-STOP Remote. Any
event which enables the Interlock on any laser
projector in the daisy chain will trigger the safety
Interlock for all the systems. After the event has
been corrected the START button on the E-STOP
Remote must be pressed by the operator to
disable the Interlock. After an Emission Delay
period the laser projectors will be ready for use.