EasyManuals Logo

KVH Industries TracVision 4 Installation & Maintenance Manual

KVH Industries TracVision 4
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
8. Type =TVG4HP<cr>.
9. Type
HALT<cr>.
10. Type DEBUGON<cr>.
11. Type
=LSTEST<cr>.
12. Type
EL,300<cr>.
13. Type
=CALGYRO<cr>. Verify that the Antenna
Gyro Azimuth scale factor is between -0.00090 and
-0.00110 and the Antenna Gyro Elevation scale
factor is between 0.00090 and 0.00110.
14. Type
=SERNUM,<serial number><cr>, where
<serial number> = the system serial number that
you recorded in Step 2.
15. Type
ZAP<cr> to restart/reinitialize the system.
KVH recommends that you complete the following additional
steps to speed satellite acquisition and improve system
performance:
16. Type
HALT<cr> while the system is performing
the limit switch initialization routine.
17. Determine your vessel’s current latitude and
longitude to the nearest degree.
18. Type
GPS,AA,B,CCC,D<cr> where:
AA = Latitude in degrees
B = N (North) or S (South)
CCC = Longitude in degrees
D = E (East) or W (West)
19. Verify that the response shows the correct
parameters.
20. Type
ZAP<cr> to restart/reinitialize the system.
Maintenance
54-0150
61

Table of Contents

Other manuals for KVH Industries TracVision 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KVH Industries TracVision 4 and is the answer not in the manual?

KVH Industries TracVision 4 Specifications

General IconGeneral
BrandKVH Industries
ModelTracVision 4
CategorySatellite TV System
LanguageEnglish

Related product manuals