2NM/2NX/2NY/2NZ/2P0/2P6
1-4-99
(13)
MP solenoid does 
not operate.
1. Defective connector 
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, replace the cable.
MP solenoid and connect right PWB (YC11)
Connect right PWB and control PWB (YC29)
2. Defective solenoid. Replace the MP solenoid.
3. Defective  connect 
right PWB.
Replace the connect right PWB (see page 2-2-36).
4. Defective PWB. Replace the control PWB and check for correct operation 
(see page 2-2-12).
(14)
Faceup solenoid 
does not operate.
(50/60 ppm model 
only)
1. Defective connector 
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, replace the cable.
Faceup solenoid and connect left PWB (YC13)
Connect left PWB and control PWB (YC2)
2. Defective solenoid. Replace the faceup solenoid.
3. Defective  connect 
left PWB.
Replace the connect left PWB (see page 2-2-36).
4. Defective PWB. Replace the control PWB and check for correct operation 
(see page 2-2-12).
(15)
The message 
requesting paper to 
be loaded is shown 
when paper is 
present on the cas-
sette.
1. Defective connector 
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, replace the cable.
High voltage PWB and engine PWB (YC19)
2. Deformed actuator of 
the paper sensor.
Check visually and replace if necessary.
3. Defective paper sen-
sor.
Replace the high voltage PWB (see page 2-2-36).
4. Defective PWB. Replace the control PWB and check for correct operation 
(see page 2-2-12).
(16)
The message 
requesting paper to 
be loaded is shown 
when paper is 
present on the MP 
tray.
1. Defective connector 
cable or poor con-
tact in the connector.
Reinsert the connector. Also check for continuity within the 
connector cable. If none, replace the cable.
MP paper sensor and connect left PWB (YC8)
Connect left PWB and control PWB (YC2)
2. Deformed actuator of 
the MP paper sensor.
Check visually and replace if necessary.
3. Defective MP paper 
sensor.
Replace the MP paper sensor.
4. Defective  connect 
left PWB.
Replace the connect left PWB (see page 2-2-36).
5. Defective PWB. Replace the control PWB and check for correct operation 
(see page 2-2-12).
Problem Causes Check procedures/corrective measures