(Page.5/11)
Service Bulletin Ref. No. 2TV-0015 (J130)
(Service information) <Date> July 19, 2019
KYOCERA Document Solutions Inc.
For authorized KYOCERA engineers only.
Do not distribute to non-authorized parties.
Peel of the carrier sheet of the double sided
tape (f) and affix 2 pcs. filter mounting holders
(e) to the louver (c) on the middle left cover and
lower left cover with the alignment below.
Press there firmly after affixing.
[Alignment]
[Front side louver (Y: right side in the top
figure)]
・Vertical: g above 20mm from h
g…Edge of the filter mounting holder
h…Bottom edge of the middle left cover (white)
・Horizontal: Edge (i) of the front side of the
main unit of the middle left cover
[Rear side louver (Z: left side in the figure)]
・Vertical: Upper edge (l) of the lower left
cover (black)
・Horizontal: The louver (c) located in the
center of circle (k) of the filter
mounting holder (e)
(Refer to the right figure)
(Refer to Procedure 1 for (c) and Procedure 3
for (f))
Insert the filter mounting holder (e) from the
upper side while pressing the left and right
edge of the dust filter (m)
Note:
・Attach the dust filter (m) in the direction in the
right figure.
・Clean the dust filter (m) using a vacuum
cleaner, etc. Standard interval to replace is 1
year and the timing depends on the installed
environment.