Last, the "regular operating power" as defined by the safety standard IEC 65/ANSI/UL 6500 and used
by a majority of safety agencies. The regular operating power is measured by using pink noise, and with
an average output power equal to 1/8 of full power. The one eighth of the total power is as loud as you
can play music while making some attempt to avoid obvious clipping. It also corresponds to a headroom
Table 2
of 9dB, which is very low for regular audio program.
SKSKN= `~äÅìä~íáçå=
e calculated as in the following example:
4 ohms load on an amplifier
, and
g to the chart above is then 1330 watts. This chart shows the active
he heat power produced is the difference between the power consumption and output power:
produced in watts, in kcal per hour, and also in BTU per hour.
he efficiency can also be calculated, it being the output-power divided by the input-power:
07 watts / 1325 watts= 38%.
Power 1/3 Power 1/8 Power Idle
[W] note 1 note 2
fP 2400Q 8 ohms 4x 360 1140 820 175
4 ohms* 4x 380 1325 840 175
2 ohms* 4x 500 2125 1440 175
* MLS at -3dB
note 1 Average power with music as program source. The amplifier driven to clip level.
note 2 Normal music power with 9dB headroom, IEC standard power rating.
MAINS INPUT POWERMAX OUTPUT POWER
The heat power can b
We consider a headroom of at least 5dB (1/3 of full power) and a
producing 380 watts per channel. The 1/3 power per channel is accordingly 380 / 3 = 127 watts
total output 4 x 127 = 507 watts.
The power consumption accordin
power consumption of the amplifier with different loads and power levels.
T
1325 – 507 = 818 watts per amplifier.
The chart below shows the heat power
1/3 Power(1)1/8 Power (2
)
1/3 Power(1) 1/8 Power (2
)
1/3 Power(1)1/8 Power (2)
[W] [W] kcal / h kcal / h BTU / h BTU / h
fP 2400Q 8 ohms 660 640 570 550 2250 2180
4 ohms 818 650 700 560 2790 2220
2 ohms 1458 1190 1250 1020 4980 4060
note 1 Average power with music as program source. The amplifier driven to clip level.
note 2 Normal music power with 9dB headroom, IEC standard power rating.
HEAT POWER
T
5
T= `lkkb`qflkp=
TKN= fåéìí=ÅçååÉÅíáçåë=
XLR Input connectors are active balanced and wired according to the IEC 268, that is pin 2 hot, and wired
ND/SHIELD
IN 2 HOT (+)
TKNKN= _~ä~åÅÉÇ=áå éìíë=
in the following way:
PIN 1 GROU
P
PIN 3 COLD (-)
i~ÄKÖêìééÉå== = = = = ====================== ========================NO
rëÉê=j~åì~ä===Ñm=OQMM=n=====sÉêëáçå=MKU========OMMPJNMJMT=

Other manuals for Lab.gruppen fP Series FP 2400Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lab.gruppen fP Series FP 2400Q and is the answer not in the manual?

Lab.gruppen fP Series FP 2400Q Specifications

General IconGeneral
BrandLab.gruppen
ModelfP Series FP 2400Q
CategoryAmplifier
LanguageEnglish

Related product manuals