EasyManua.ls Logo

LaboGene ScanSpeed 1248 User Manual

Default Icon
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Revision : 01
Date : 2013.05.07
Cat. No. : 9.900.900.578
INSTRUCTION MANUAL
MULTI-PURPOSE, HIGH SPEED CENTRIFUGE
ScanSpeed 1248
Question and Answer IconNeed help?

Do you have a question about the LaboGene ScanSpeed 1248 and is the answer not in the manual?

LaboGene ScanSpeed 1248 Specifications

General IconGeneral
BrandLaboGene
ModelScanSpeed 1248
CategoryLaboratory Equipment
LanguageEnglish

Summary

Meanings of Symbols & Safety Precautions

Meanings of Symbols

Explains symbols used on the device and in the document for warnings and reminders.

Safety Precautions

Lists essential safety guidelines for operating the centrifuge and handling samples to prevent injury or damage.

Product Description & Technical Specifications

Product Description

Provides an overview and diagram of the ScanSpeed 1248 centrifuge, detailing its main components.

Technical Specifications

Details the performance, dimensions, power requirements, and key features of the ScanSpeed 1248 centrifuge.

Installation

Power On/Off and Door Release

Instructions for powering the instrument on/off and safely releasing the centrifuge door.

Rotor Coupling and Disassembling

Steps for correctly attaching and detaching rotors, including swing-out and fixed angle types.

Positioning of Sample Tubes

Guidelines for properly loading sample tubes into the rotor for balanced operation and safety.

Operation

Control Panel Functions

Explains the purpose and usage of each button and display element on the centrifuge's control panel.

Setting Rotational Speed and Force

Detailed steps for setting the rotational speed (RPM) and relative centrifugal force (RCF) for centrifugation.

Setting Centrifugation Time

Instructions on how to set the centrifugation duration, including minute and second increments.

Acceleration and Deceleration Control

How to adjust acceleration and deceleration rates for protecting sensitive samples during runs.

Program Saving and Recalling

Guide on how to save custom settings and recall previously stored programs for repeat runs.

Pulse Operation

Describes the function of the 'Pulse' button for quick, short spins.

Start and Stop Operation

Instructions on how to start and stop the centrifugation process using the control panel.

Emergency Door Opening Procedure

Procedure for manually opening the centrifuge door in case of power failure or other emergencies.

Fuse Replacement Guide

Steps for safely replacing the fuse if the instrument does not power on.

Maintenance

Cleaning Outer Instrument Parts

Cleaning instructions for the external surfaces of the centrifuge.

Chamber Cleaning and Drying

Guidance on cleaning and keeping the internal chamber dry after use.

Motor Shaft Care

Recommendations for cleaning the motor shaft to prevent imbalance issues.

Rotor Maintenance and Storage

Advice on cleaning rotors, avoiding scratches, and proper storage.

Instrument Transportation Guidelines

Precautions to take when moving or shipping the centrifuge to protect internal components.

Troubleshooting

Troubleshooting Check List

A list of common symptoms and their potential causes and checks to resolve issues.

Error Code Explanations

Explanation of error codes displayed by the instrument and recommended actions for each.

Related product manuals