13
Operations
Shutting Down And
Clean-up
STEP 1: Remove detergent suction
tube from container and insert into
one (1) gallon of fresh water. Pull
trigger on spray gun and siphon
water for one minute.
STEP 4: Squeeze trigger on spray
gun to relieve remaining pressure.
STEP 2: Turn burner switch off and
continue spraying, allowing the
water to cool to below 100°F.
STEP 5: Remove water supply
hose.
STEP 3: Turn engine key switch off
and turn off water.
STEP 6: Disconnect high pressure
hose from high pressure outlet.
Landa PGDC Operator’s Manual 8.916-596.0 - P
Burner
Switch
Engine
Key Switch