7
Convert Valves:
- Remove control knobs.
- Using small flat head screw driver adjust the minimum rate screw as
follows:
For Natural Gas - Counterclockwise to stop.
For Liquid Propane - Clockwise to stop
- Reinstall control knobs.
Note: The minimum rate screw setting for Natural Gas is turned all the
way counterclockwise, for LP it should be turned all the way clockwise.
Gas Conversion
36
6
Convert regulator:
- Use adjustable wrench to remove regulator cap.
- Unscrew regulator stem, turn over and then reinstall.
- See diagram below for correct assembly of conversion
gas type.
- Reinstall regulator cap tightly.
Cap
8
Record Conversion:
- The appliance rating label is located underneath the control panel
- Install conversion label supplied with the conversion kit over the
left side of the rating label.
- Place parts that were removed for this conversion back in the
parts bag for possible future use.
9
- Connect to gas source
- Check for leaks (see Checking for Leaks page).
For Natural Gas
For LP Gas
Cap
Stem