supply voltage | 10.8 - 3 V, 9 - 30 V |
---|---|
current consumption with active sensor | 20 mA max |
range of service temperatures | -30/+0°C, -25/+70°C |
---|---|
frequency of ultrasound | 40 KHz |
Apply primer, then spray paint, and finally transparent paint, allowing drying time.
Drill 4mm holes and fit sensors using specified angled brackets (Ø18, Ø22, Ø24).
Connect sensor cables and power to the main unit using provided connectors.
Long press buttons to activate service state and select parameter number.
Use buttons to choose parameter and change its value; value blinks during modification.
Long press to store new value; reinsert reverse gear to confirm changes.
Restore default parameters by holding buttons until 'FS - FACTORY SETTING' is displayed.
Adjust sensitivity and detection range for rear central and corner sensors.
Adjust detection range and define STOP zones for front sensors.
Perform initial tests by placing obstacles and checking display feedback.
Check function n.1 and speaker/display connection if no acoustic signal.
System indicates faulty sensors with beeps or display errors (E).
Check for dirty sensors, low installation, or contact with vehicle chassis.
Clean sensors, use angled supports, separate sensors, or select function n.49.