EasyManuals Logo

LaserLine EPS4016 User Manual

Default Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
PARAMETERS SETTING
Pag.21
.
Functioning description
Func.
Num.
Volume of speaker
volume OFF00
LOW volume01
()02 factory setting - FSHIGH volume
01
Delay of MUTE function deactivation
not active active for 1 second active for 2 seconds,00 , 01 , 02
03 04 active for 3 seconds, active for 4 seconds
s ()05 FSactive for 5 second
07
10
Service display
00 (FS)not active
01 distance of nearest front obstacle [cm]
distance of nearest rear obstacle [cm]02
speed of vehicle (only with connected speed signal)03
learning of speed signal pulses04
version of ECU software05
power supply voltage [Volt]06
07 temperature of front unit [°C]
temperature of rear unit C]08
.
02
Type of unit
01 Front
()02 FSRear
Number of speed pulses
[impulses/m]01 - 99 FS= 03
(to this value is added value from parameter “09")
08
Fine adjustment of speed pulses
[impulses/m]0,0 - 0,9 FS= 0,0
09
All the parameters that the user can change, are listed in the following table and can be
modified using the buttons on the control unit.
WARNING! he irresponsible use of the settings can seriously limit the erformance of the t p
device.
18
Engine noise filter
00 OFF (FS)
ON01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LaserLine EPS4016 and is the answer not in the manual?

LaserLine EPS4016 Specifications

Power IconPower
supply voltage10.8 - 3 V, 9 - 30 V
current consumption with active sensor20 mA max
Operating Environment IconOperating Environment
range of service temperatures-30/+0°C, -25/+70°C
frequency of ultrasound40 KHz