21
Volume of front LED indicator
)00 factory setting - FS (volume OFF
LOW volume01
HIGH volume ( )02 - FSEPS4016-BZ
23
Sensitivity of front sensors
=-9 - +9 FS 00
22
Orientation of front LED indicator
()00 FSdefault
change left and right side01
20
Number of front sensors connected
=02,03,04 FS 04
25
Range of front central sensors
[cm] = above 100cm display45 - 120 FS 85
shows 10 - 12
FRONT unit setting.
NOT SELECT when used as rear system.
26
Range of front corner sensors
[cm] =45 - 90 FS 60
27
Range of front central sensors STOP zone
[cm] =30 - 50 FS 35
28
Range of front sensors STOP zonecorner
[cm] =30 - 50 FS 35
29
Suppression of front protruding parts
()00 FSdisabled function
exclusion of the protruding parts from bumper in Cm05,10,15,20,25,30
99 automatic exclusion of the protruding parts
!!! NOTE: change only if there is an overhang, eg. number plate or other,
increase the value until the protrusion is no longer detected by the parking
system
32
Detection of very close obstacles
00 FS ()not active
active01
34
Acoustic signal timed of an obstacle in the F1 and F2 areas
01 (FS)disabled function after 1 second
timing, in step of operation sensors (seconds)0,2 03 - 10
99 constant signalling of obstacles
35
State of front sensors after turn ON of front unit
not active00
()01 FSactive
36
State of front corner sensors after front sensors activation
(FS)00 all sensors active
corner sensors active only with reverse gear connected to01
Enable input (operation with the connection of the yellow / Blue
pin.7)
37
Delay of front sensors deactivation - time window
- [s] =00 60 FS 20
PARAMETERS SETTING ONLY FOR FRONT SYSTEM
Pag.23

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LaserLine EPS4016 and is the answer not in the manual?

LaserLine EPS4016 Specifications

Power IconPower
supply voltage10.8 - 3 V, 9 - 30 V
current consumption with active sensor20 mA max
Operating Environment IconOperating Environment
range of service temperatures-30/+0°C, -25/+70°C
frequency of ultrasound40 KHz