LAVAZZA LB 2500 PLUS - ALARM MESSAGES ON THE DISPLAY

LAVAZZA LB 2500 PLUS
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
EN
ALARM MESSAGES ON THE DISPLAY
Display Machine status Events Remedies
LAVAZZA LB PLUS
Drawer full
Used capsules drawer full
Soluble drink dispensing
is possible
Empty drawer and wash it
LAVAZZA LB PLUS
Drawer full
Drawer opened with
machine at
temperature
Not possible to
dispense
Close the drawer
WARNING
No water
No water in the tank or
tank missing
Selection buttons ashing
Fill the tank with non-
carbonated fresh drinking
water
WARNING
Door open
Soluble element door
open
Not possible to dispense
Close the soluble element
door
OVERHEATING
WAIT
Temperature too high Not possible to dispense
Wait for machine to cool
down. If the message
does not disappear,
contact the service
engineers
WAIT FOR COOLING
DOWN
Machine components
cooling down
Not possible to dispense
Wait for components to
cool. If the message does
not disappear, contact
the service engineers
CREDIT
USED UP
Credit used up Not possible to dispense Reload credit
DISPENSING
TIMEOUT
Dispensing terminated
due to absence of water
ow
Incomplete product
dispensing
Carry out start pumps
procedure. If the message
remains or the pumps
fail to start, contact the
service engineers
INSERT CREDIT
Insert credit, when
dispensing is by payment
and there is no credit left
Not possible to dispense Reload credit
WARMING UP
ALARM
Warming up has not
succeeded
Not possible to dispense Contact service engineers
FAULT ON FLOW
METER
Flow meter faulty,
number of pulses not
reached
Not possible to dispense Contact service engineers
SENSOR ALARM
Sensor alarm (shorted or
open)
Not possible to dispense Contact service engineers
NEGATIVE START
PUMPS
Negative result on start
pumps
-
Repeat operation. In
case of a negative result,
contact service engineers
DESCALING
REQUIRED
The machine needs
descaling of the hydraulic
circuit
The dispensing of all
products is possible
Run the descaling cycle
as described in chapter
"Maintenance and
cleaning”
REPLACE SOFTENER
The water softener lter
has exhausted its ltering
capacity
The dispensing of all
products is possible
Replace the water
softener lter

Table of Contents