NOTICE
Removal of battery during operation or shutdown
This can result in a le system error and data loss!
1942_002
Precautions:
Do NOT remove the battery during operation of the instrument, or during
the shutdown procedure.
Always switch off the instrument by pressing the On/Off key, and wait
until the instrument has shutdown completely before removing the bat-
tery.
CAUTION
Not properly secured accessories
If the accessories used with the product are not properly secured and the
product is subjected to mechanical shock, for example blows or falling, the
product may be damaged or people can sustain injury.
Precautions:
When setting up the product, make sure that the accessories are correctly
adapted, tted, secured, and locked in position.
Avoid subjecting the product to mechanical stress.
WARNING
Exposure of batteries to high mechanical stress, high ambient temper-
atures or immersion into uids
This can cause leakage, re or explosion of the batteries.
Precautions:
Protect the batteries from mechanical inuences and high ambient tem-
peratures. Do not drop or immerse batteries into uids.
WARNING
Short circuit of battery terminals
If battery terminals are short circuited e.g. by coming in contact with jewellery,
keys, metallised paper or other metals, the battery can overheat and cause
injury or re, for example by storing or transporting in pockets.
Precautions:
Make sure that the battery terminals do not come into contact with
metallic objects.
8 Safety Directions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leica BLK2GO and is the answer not in the manual?

Leica BLK2GO Specifications

General IconGeneral
TypeHandheld Imaging Laser Scanner
ConnectivityWi-Fi, USB-C
AccuracyUp to 6 mm at 10 m
IP RatingIP54
Scanning RangeUp to 25 m
Laser ClassClass 1
Scan Rate420, 000 points per second
Field of ViewVertical: 360°, Horizontal: 270°
Operating Temperature0°C to 40°C (32°F to 104°F)
Data FormatsE57, RCP, PTX
Software CompatibilityLeica Cyclone REGISTER 360, Leica Cyclone FIELD 360
Weight775 g (1.7 lbs), including battery
Data StorageInternal storage (expandable via microSD card)