GR30/GM30/GR50, GR30/GM30 User Interface
34
RT out data
stream LED
off No active data stream is configured or power is off.
green One or more data streams are configured and active.
Data is being streamed.
red Data streams are active but no data is streamed.
Recommended user action: Check that
satellites are tracked and a navigated position
is available. Check that the correct reference
position is entered.
RT in data stream
LED
off No active real time in data stream or power is off.
green A real time in data stream is configured and active,
data is received and a fixed position is available.
flashing
green
A real time in data stream is configured and active,
data is received and a DGPS position is available.
yellow A real time in data stream is configured and active,
data is received but no fixed or DGPS position is avail-
able.
red Incoming data streams are active but no data is
received.
OR
Incoming data stream is configured and active but
the instrument is not tracking satellites and/or no
navigated position is available.
Recommended user action: Check that the
incoming data connection is set up correctly. Check
the tracking and position of the instrument.
Position LED off The instrument is switched off.
flashing
green
The instrument is tracking satellites but no position
is available.
green A navigated position is available.
red No satellites are tracked and no navigated position is
available.
IF the is THEN