EasyManua.ls Logo

Leica Sprinter 150 - Technical Data

Leica Sprinter 150
380 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Technical Data
Sprinter 150/150M/250M - 1.0.0en
EN
DE
FR
ES
NO
SV
FI
DA
IT
PT
NL
13. Technical Data
Height measurements Standard deviation per km double run (ISO 17123-2):
Electronic measurement with Sprinter aluminum barcode staff:
1.0 mm (Sprinter 250M)
1.5 mm (Sprinter 150/150M)
Optical measurement with standard aluminum E-scale/Numeral staff: 2.5 mm
Standard Deviation for single staff reading: 0.6 mm (electronic) and 1.2 mm (optical) at 30m
Distance Accuracy
(Standard Deviation)
10 mm for D<= 10 m
Distance in m x 0.001 for D>10 m
Range Distance measuring range for electronic measurements with standard aluminum barcode staff: 2 m to
100 m.
Optical - Shortest focusing
distance
50 cm
Measuring time single
measure (Electronic)
Typically 3 seconds and less in normal daylight condition; needs longer measuring time in uniform dim
light condition (20 lux).
Circular Bubble Circular Bubble Sensitivity: 10'/2 mm
Compensator Magnet damped pendulum compensator with electronic range monitoring
Tilt Warning Range (Electronically): ± 10'
Compensator range (Mechanically): ± 10'
Setting accuracy: 0.8" max. (Standard Deviation)
Magnetic field sensitivity: < 10"
(Line-of-sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss)
RS232 Port* For RS232 cable connection to external battery and communication to PC / data collector.
Phone Jab Port* For USB cable connection to communication to PC.

Table of Contents

Related product manuals