20
Technical data COMET
Length of wedge mm 95 70 50 20
Voltage
V~
(Mains voltage cannot be switched over)
230 120, 230 120, 230 120, 230
Power consumption W 1850 1500 1200 700
Frequency Hz 50 / 60 50 / 60 50 / 60 50 / 60
Temperature infinitely variable max. 420 max. 420 max. 420 max. 420
Mark of conformity 2 2 2 2
Protection class I 1 1 1 1
Technical data and specifications are subject to change without prior notice
COMET, tunnel construction, groundworks and hydraulic engineering
Length of wedge mm 95 70 50 20
Width hot wedge mm
Other wedge seam widths on request
50 50 50 30
Weld seam width mm
(refers to hot wedge with testing channel)
2 × 15 2 × 15 2 × 15 2 × 10
Welding pressure, infinitely variable N max. 1000
Drive, infinitely variable m / min. 0.8 – 3.2
Weight without power supply cord kg 7.0
Dimensions L × W × H mm 295 × 250× 245
COMET, sub-roof films and sealing membranes
Length of wedge mm 20
Width hot wedge mm
Other wedge seam widths on request
30
Welding pressure, infinitely variable N max. 500
Drive, infinitely variable m / min. 0.8 – 6.0
Weight without power supply cord kg 7.5
Dimensions L × W × H mm 355 × 250 × 245