Operating Instructions 5-9
D-H021.1011EN
innovators in agriculture
Note:
The sample box, with trays and disposable bottles, is provided by CRV
Nederland.
Preparation
1. Take the milking robot out of operation with the X-Link. Refer to
the Operator Manual of the milking robot for more information.
2. Select tab [Sampling].
3. Select button [Change rack].
Removal
1. Loosen the fasteners (11) and open the cover of the SHUTTLE.
2. Remove the second rack (2).
3. Remove the first rack (1).
4. Close the bottles.
5. Remove the sample box from the SHUTTLE.
Installation
1. Remove the cover from the sample box.
WARNING
The content of the sample box contains poisonous substances
necessary to preserve the milk samples. There is a danger of damage
to health when:
- large quantities of the preservative are inhaled
- the preservative comes in contact with the skin
- the preservative is swallowed.
2. Open the lid of each bottle to 90°.
CAUTION
Do not use a not flat or bent sample box.
3. Install the sample box in the SHUTTLE base. The sample box can
only be installed one way.
4. Install the first rack (1).
5. Install the second rack (2).
6. Make sure the lids are open and between the racks.
Note:
The cover can only by closed if the racks are correctly installed.
WARNING