5-10 Operating Instructions
D-H021.1011EN
innovators in agriculture
7. Close and lock the cover of the SHUTTLE.
If the cover can not be closed, make sure the racks are installed
correctly and try again.
Close-up
1. Put the milking robot in operation with the X-Link. Refer to the
Operator Manual of the milking robot for more information.
5.4 Disconnect the Sampling Device
Preparation
1. Take the milking robot out of operation. Refer to the Operator
Manual of the milking robot for more information.
X-Link adjustments
1. Select tab [Sampling].
2. Select button [Turn sampling off].
3. Select button [Stop].
4. The sampling is stopped.
5. Select button [Open].
6. Remove the milk tube from the elbow.
7. Put the stop in the elbow.
8. Remove the milk tube from the sampling cylinder.
9. Select button [Close].
10. Disconnect the CAN-bus cable from the E-Link connector on the
multiple function box.
T4C adjustments
Note:
It is not necessary to disable milk sampling in T4C if more sample runs must
be done in the future.
1. For a farm with T4C 1 software, do the following:
1. Select survey tab [Farm].
2. Select the applicable herd.
3. Select module tab [Milking].
4. Select button [Settings].
5. Select worksheet tab [General].
6. Deselect checkbox 'Sampling'.
7. Select button [Submit].
2. For a farm with T4C 3 software, do the following:
1. In the navigation bar, select 'Data Entry' and 'Settings'.
2. Select tab 'Milking'.