9.0. MAINTENANCE
Regular maintenance and service should be peormed by authorised personnel to prolong the
unit life span.
9.1. Outdoor Heat Exchanger
Outdoor heat exchanger is required to be cleaned once every two months.
Use a vacuum cleaner with nylon brush to clean up dust and sundries on the suace of heat
exchanger.
Blow away dust by compressed air if it is available.
Never use water to wash the heat exchanger.
9.2. Drain Pipe
Regularly check the drain pipe to ensure it is not blocked and condensate can be drained freely.
9.3. Maintenance Before Usage Season
Check the inlet/outlet of the indoor/outdoor unit is not blocked.
Check the ground wire is earthed.
Check the battery of remote wireless controller has been replaced.
Check the filter screen has been set soundly.
Aer long period of shutdown, turn on the main power switch 8 hours before re-operating the unit
so as to preheat the compressor crankcase.
9.4. Maintenance Aer Usage Season
Cut o main power supply of the unit.
Clean filter screen and indoor and outdoor units.
Clean the dust and sundries on the indoor and outdoor units.
In the event of corrosion, use the anti-rust paint to stop spreading of rust.
13 23 50 | lennoxaus.com.au
LENNOX MULTI SPLIT INVERTER
Outdoor Unit
CAUTION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox 4 Series and is the answer not in the manual?

Lennox 4 Series Specifications

General IconGeneral
BrandLennox
Model4 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals