3.3. Rated Working Conditions
Table 3: Rated Working Conditions
Indoor Side State Outdoor Side State
Dry Bulb Temp. °C Wet Bulb Temp. °C Dry Bulb Temp. °C Wet Bulb Temp. °C
Rated Cooling 27 19 35 24
Rated Heating 20 15 7 6
NOTICE:
The listed cooling and heating capacity is tested before outgoing.
The parameters are tested under rated working conditions. Refer to name plate for any amendments
to test results.
The parameters of heating capacity of indoor unit for heat pump exclude that of auxiliary electric
heating power.
The peormance parameters are tested according to standard AS/NZS 3823.2-2013.
3.4. Operating Temperature Ranges
Table 4: Operating Temperature Ranges
Model Mode Outdoor Temperature Range
LNMT100V4 Cooling -7°C - 48°C
Heating -15°C - 24°C
LNMT114V4 Cooling -7°C - 48°C
Heating -15°C - 30°C
13 23 50 | lennoxaus.com.au
LENNOX MULTI SPLIT INVERTER
Outdoor Unit