Page 15
Use PVC primer and solvent cement or ABS solvent ce-
PHQW PHHWLQJ $670 VSHFL¿FDWLRQV UHIHU WR7$%/(
As an alternate, use all purpose cement, to bond ABS,
39&RU&39&SLSHZKHQXVLQJ¿WWLQJVDQGSLSHPDGHRI
the same materials. Use transition solvent cement when
bonding ABS to either PVC or CPVC.
Low temperature solvent cement is recommended during
cooler weather. Metal or plastic strapping may be used for
vent pipe hangers. Uniformly apply a liberal coat of PVC
primer for PVC or use a clean dry cloth for ABS to clean
LQVLGH VRFNHW VXUIDFH RI ¿WWLQJ DQG PDOH HQG RI SLSH WR
GHSWKRI¿WWLQJVRFNHW
Canadian Applications Only - 3LSH¿WWLQJVSULPHUDQG
VROYHQWFHPHQWXVHGWRYHQWH[KDXVWWKLVDSSOLDQFHPXVW
EHFHUWL¿HGWR8/&6DQGVXSSOLHGE\DVLQJOHPDQX-
IDFWXUHUDVSDUWRIDQDSSURYHGYHQWH[KDXVWV\VWHP,Q
DGGLWLRQWKH¿UVWWKUHHIHHWRIYHQWSLSHIURPWKHIXUQDFH
ÀXHFROODUPXVWEHDFFHVVLEOHIRULQVSHFWLRQ
TABLE 3
OUTDOOR TERMINATION USAGE*
Input
6L]H
Vent Pipe
Dia. in.
STANDARD CONCENTRIC
Flush
Mount Kit
Wall Kit
Wall Ring
Kit
Field
Fabricat-
ed
1-1.2 inch 2 inch 3 inch
2 inch 3 inch 2 inch
71M80
(US)
4
44W92
(CA)
69M29
(US)
4
44W92
(CA)
60L46 (US)
4
44W93
(CA)
51W11
(US)
51W12
(CA)
22G44
(US)
4
30G28
(CA)
44J40
(US)
4
81J20
(CA)
15F74
030,
045
6
1-1.2
3
YES YES
1
YES
1
YES
5
YES
2
YES
2
3
YES YES
1
YES
1
YES
5
YES
2
YES
2-1/2
3
YES YES
1
YES
1
YES
5
YES
2
YES
3
3
YES YES
1
YES
1
YES
5
YES
2
YES
070
6
1-1/2
3
YES YES
1
YES
1
YES
5
YES
2
YES
2
3
YES YES
1
YES
1
YES
5
YES
2
YES
2-1/2
3
YES YES
1
YES
1
YES
5
YES
2
YES
3
3
YES YES
1
YES
1
YES
5
YES
2
YES
090
2
3
YES YES YES
5
YES YES YES
2-1/2
3
YES YES YES
5
YES YES YES
3
3
YES YES YES
5
YES YES YES
110
2 YES YES YES
5
YES YES YES
2-1/2 YES YES
5
YES YES YES
3 YES YES
5
YES YES YES
NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total
vent length calculations. See vent length tables.
* Kits must be properly installed according to kit instructions.
5HTXLUHV¿HOGSURYLGHGRXWGRRU´H[KDXVWDFFHOHUDWRU
2Concentric kits 71M80 and 44W92 include 1-1/2” outdoor accelerator, when uses with 030, 045 and 070 input models. When using 1-1/2 inch vent pipe, transistion to 2”
pipe before installing concentric kit.
3 Flush mount kits 51W11 and 51W12 includes 1-1/2 in. outdoor exhaust accelerator, required when used with 030, 045, 070 and 090 input models. When using 1-1/2”
YHQWSLSHWUDQVLWLRQWR´SLSHEHIRUHLQVWDOOLQJÀXVKPRXQWNLW
7HUPLQDWLRQNLWV*:DQG-DUHFHUWL¿HGWR8/&6IRUXVHLQ&DQDGDRQO\
5 See table 8 for vent accelerator requirements.
5HTXLUHV¿HOGSURYLGHG´WR´UHGXFHU