Packaged Electric / Electric 26 to 44 kW 50 Hz / Page 14
OPTIONS / ACCESSORIES
Item Description
Model
Number
Catalog
Number
Unit Model No
092 102 120 150
CE MARK
CE Marked Unit Factory O O O O
COOLING SYSTEM
Condensate Drain Trap Polyvinyl Chloride (PVC) - C1TRAP20AD2 22H54 OX OX OX OX
Copper - C1TRAP10AD2 76W27 OX OX OX OX
Conventional Fin/Tube Condenser Coil (replaces Environ™ Coil System) Factory O O O
Corrosion Protection Factory O O O O
 E1SNSR71AD1 21Z07 OX OX OX OX
Refrigerant Type R-410A O O O O
Service valves (not for Environ™ Coil System or Humiditrol
®
equipped units) Factory O O O O
BLOWER - SUPPLY AIR
Motors Belt Drive - 1.5 kW (2 hp) Factory O O O O
Belt Drive - 2.2 kW (3 hp) Factory O O O O
Belt Drive - 3.7 kW (5 hp) Factory O O O O
Drive Kits
See Blower Data Tables for selection
Kit #1 490 - 740 rev/min Factory O O O O
Kit #2 665 - 920 rev/min Factory O O O O
Kit #3 660 - 995 rev/min Factory O O O O
Kit #7 610 - 810 rev/min Factory O O O O
Kit #8 780 - 1000 rev/min Factory O O O O
Kit #9 845 - 1085 rev/min Factory O O O O
Kit #10 750 - 945 rev/min Factory O O O O
Kit #11 865 - 1095 rev/min Factory O O O O
Kit #12 940 - 1190 rev/min Factory O O O O
Blower Belt Auto-Tensioner Factory O O O O
CABINET
Combination Coil/Hail Guards Furnished Environ™ Coil System - C1GARD52B-1 13T05 X X X
Optional Conventional Fin/Tube Condenser Coil - E1GARD51B-1 13T04 X X X
Furnished Conventional Fin/Tube Condenser Coil System - C1GARD52B-1 13T05 X
Horizontal Discharge Kit K1HECK00B-1 51W25 X X X X
Return Air Adaptor Plate (for LC/LG/LH and TC/TG/TH unit replacement) C1CONV10B-1 54W96 OX OX OX OX
CONTROLS
Blower Proving Switch C1SNSR35FF1 21Z10 OX OX OX OX
Commercial Controls Prodigy
®
Control System - BACnet
®
Module - C0CTRL60AE1L 59W51 OX OX OX OX
Prodigy
®
Control System - LonTalk
®
Module - C0CTRL65FF1 54W27 OX OX OX OX
Novar
®
LSE Factory O O O O
Dirty Filter Switch E1SNSR55B-1 53W67 OX OX OX OX
General Purpose Control Kit E1GPBK30C1 13J78 X X X X
Fresh Air Tempering C1SNSR75AD1 21Z08 OX OX OX OX
Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44B-2 11K76
OX OX OX OX
Smoke Detector - Supply and Return (Power board and two
sensors)
C1SNSR43B-2 11K80
OX OX OX OX



X = Field Installed