Energence
®
Packaged Electric / Electric 26 to 44 kW 50 Hz / Page 4
FEATURES AND BENEFITS

Conventional Fin/Tube Condenser Coils
(150 models only, optional 092-120 models)
Copper tube construction

Flared shoulder tubing connections
Silver soldered construction
Evaporator Coil
Copper tube construction

Flared shoulder tubing connections
Silver soldered construction
Factory leak tested

Condensate Drain Pan
Plastic pan, sloped to meet drainage requirements per

Side or bottom drain connections
Reversible to allow connection at back of unit
Outdoor Coil Fan Motors
Thermal overload protected
Totally enclosed
Permanently lubricated ball bearings
Shaft up
Wire basket mount
NOTE - All 150 models feature two-speed motors for
optimal performance at low ambient conditions.
Outdoor Coil Fans

Required Selections
Cooling Capacity
Specify nominal cooling capacity
Options/Accessories
Factory Installed
Conventional Fin/Tube Condenser Coil
(replaces Environ™ Coil System - 092 through 120
models only)
Copper tube construction

Flared shoulder tubing connections
Silver soldered construction
NOTE
Service Valves
Fully serviceable brass valves installed in discharge &
liquid lines
NOTE - Not available for units equipped with Environ™ Coil
System or Humiditrol
DD
Factory or Field Installed
Condensate Drain Trap

Field installed only, may be factory ordered to ship with
unit

Monitors condensate level in drain pan
Shuts down unit if drain becomes clogged
CABINET
Construction
Heavy-gauge steel panels
Full perimeter heavy-gauge galvanized steel base rail
Base rails have rigging holes
Three sides of the base rail have forklift slots
Raised edges around duct and power entry openings in
the bottom of the unit for water protection



NOTE
with optional Horizontal Discharge Kit.
Duct Flanges
Provided for horizontal duct attachment
Power Entry
Electrical lines can be brought through the unit base or
through horizontal access knock-outs
Exterior Panels
Constructed of heavy-gauge, galvanized steel

Insulation

insulation (conditioned areas)
Unit base is fully insulated
Base insulation serves as an air seal to the roof curb,
eliminating the need to add a seal during installation
Hinged Access Panels
Tool-less access
Filter section


Panel seals and quarter-turn latching handles provide a
tight air and water seal
Required Selections


EE
FF