Energence
®

COOLING SYSTEM
Designed to maximize sensible and latent cooling
performance at design conditions
System can operate from -18°C to 52°C without any
additional controls
R-410A Refrigerant
Non-chlorine based
Ozone friendly
Scroll Compressors
Scroll compressors on all models for high performance,
reliability and quiet operation
Resiliently mounted on rubber grommets for quiet
operation
Compressor Crankcase Heaters
Protects against refrigerant migration that can occur
during low ambient operation
Thermal Expansion Valves
Assures optimal performance throughout the application
range
Removable element head
Filter/Driers

and moisture
High Pressure Switches
Protects the compressors from overload conditions

loss of outdoor fan operation
Low Pressure Switches
Protects the compressors from low pressure conditions

BB
PERFORMANCE/QUALITY AND CE MARK OPTION
PERFORMANCE/QUALITY
Cooling performance is rated at test conditions included in Air-Conditioning, Heating and Refrigeration Institute (AHRI)

Components bonded for grounding to meet safety standards for servicing required by Underwriters Laboratories (UL)
and the International Electrotechnical Commission (IEC)
International Organization for Standardization (ISO) 9001 Registered Manufacturing Quality System
CE MARK OPTION

This optional construction allows units to be sold into countries requiring CE marking for rooftop products



Key features of this option over and above standard product features are:

Branch circuits over 0.5 kW load have overcurrent protection

power on
Padlock can be applied to lock the disconnect switch in the OFF position
The factory wiring has been redesigned for separation of high and low voltage circuits
FEATURES AND BENEFITS
Freezestats
Protects the evaporator coil from damaging ice build-

refrigerant charge
Condenser Coil - Environ™ Coil System
(092 through 120 models only)
Lightweight, all aluminum brazed

Constructed of three components


extrusion tube
Two refrigerant manifolds
Environ™Coil System Features:
Improved heat transfer performance due to high primary

Smaller internal volume (reduced refrigerant charge)
High durability
All aluminum construction
Fewer brazed joints
Compact design
Reduced unit weight

Face split design
Mounting brackets with rubber inserts secure coil to unit
providing vibration dampening and corrosion protection
CC