© 2003 Lennox Industries Inc.
Corp. 0124−L11
G60UHV(X)
Service Literature
Revised 1−2009
G60UHV(X) SERIES UNITS
G60UHV(X) series units are mid−efficiency gas furnaces
used for upflow or horizontal applications only, manufac-
tured with Lennox Duralok Plus heat exchangers formed of
aluminized steel. G60UH(X) units are available in heating
capacities of 66,000 to 132,000 Btuh and cooling applica-
tions up to 5 tons. Refer to Engineering Handbook for prop-
er sizing.
Units are factory equipped for use with natural gas. Kits are
available for conversion to LPG operation. G60UH(X) model
units are equipped with the Two−Stage / Variable Speed Inte-
grated SureLight control. G60UH(X) unit meets the Califor-
nia Nitrogen Oxides (NO
x
) Standards and California Sea-
sonal Efficiency requirements. All units use a redundant gas
valve to assure safety shut−off as required by C.S.A.
All specifications in this manual are subject to change. Pro-
cedures outlined in this manual are presented as a recom-
mendation only and do not supersede or replace local or
state codes. In the absence of local or state codes, the
guidelines and procedures outlined in this manual (except
where noted) are recommendations only and do not consti-
tute code.
TABLE OF CONTENTS
Introduction Page 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications Page 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Data Page 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Altitude Page 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Components Page 9. . . . . . . . . . . . . . . . . . . . . . . .
II Installation Page 32. . . . . . . . . . . . . . . . . . . . . . . . . . . .
III Start Up Page 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IV Heating System Service Checks Page 33. . . . . . . . .
V Typical Operating Characteristics Page 35. . . . . . . . .
VI Maintenance Page 36. . . . . . . . . . . . . . . . . . . . . . . . . .
VII Wiring and Sequence of Operation Page 38. . . . . .
VIII Field Wiring and Jumper Settings Page 53. . . . . . .
IX Troubleshooting Page 58. . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a qualified installer, service agency
or the gas supplier.
WARNING
Electric shock hazard. Can cause injury
or death. Before attempting to perform
any service or maintenance, turn the
electrical power to unit OFF at discon-
nect switch(es). Unit may have multiple
power supplies.
WARNING
Sharp edges.
Be careful when servicing unit to avoid sharp edges
which may result in personal injury.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox G60UHV and is the answer not in the manual?

Lennox G60UHV Specifications

General IconGeneral
Heating StagesTwo-Stage
Blower MotorVariable Speed
Fuel TypeNatural Gas
Ignition SystemHot Surface Ignition
ConfigurationUpflow/Horizontal
Heating Capacity44, 000 to 132, 000 BTU/h
WarrantyLimited Lifetime Heat Exchanger Warranty, 5-Year Limited Warranty on covered components

Related product manuals