EasyManuals Logo

Lennox GAH 020S User Manual

Lennox GAH 020S
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
• 7 •
GA C 020 S M 1 M
LNCJ
SEAS
HIFP
ACTR
CPGR
LLWT
PHRF
RLKD
SPLP
DPLP
SPEL
DPEL
SPHP
DPHP
SPEH
DPEH
BYVC
WTNG
WTHS
WTHH
EWFS
WFIF
KGRL
APEP
APPP
APPW
ECLO
BNET
MBUS
MBIP
DM60
DS60
DCBO
ELME
PHCT
POWF
SOFT
EBFM1
EBFM2
ALWA
AVUB
SLCR
Installation manual /eCOMFORT-MIL150E-0916 / 05/2017
1.- GENERAL CHARACTERISTICS
C: Cooling only units
H: Heat pump units
Approximately capacity in kW
S: Single circuit
D: Dual circuit
M: Refrigerant R410A
M: 400V/3/50 Hz
1.1.- TECHNICAL DATA
Type of unit eCOMFORT
1 : Revision 1
OPTIONS
Low noise : Accoustic compressor jacket
Variable air ow control with standard EC fans
Variable air ow control with high pressure EC fans
LenGuard anti-corrosion condenser coil treatment
Coils protection : metallic grille
Low leaving water temperature down to -12°C
Domestic hot water supply : desuperheater
Refrigerant leak detection
Hydraulic module with low-pressure single pump
Hydraulic module with low-pressure twin pump
Hydraulic module with eDrive low-pressure single pump
Hydraulic module with eDrive low-pressure twin pump
Hydraulic module with high-pressure single pump
Hydraulic module with high-pressure twin pump
Hydraulic module with eDrive high-pressure single pump
Hydraulic module with eDrive high-pressure twin pump
Bypass Valve for delta P control with eDrive pump (supplied loose)
Water tank
Water tank electrical heater Standard
Water tank electrical heater High
Electronic ow switch
Water lter (supplied loose)
Flange connection (supplied loose)
Antifreeze protection on exchangers and pipings down to -20°C
Antifreeze protection on exchangers, pump(s) piping down to -20°C
Antifreeze protection on exchangers, pump(s) piping and water tank down to -20°C
LonWorks® interface FTT10
BACnet® interface MSTP
ModBus interface RS485
ModBus and BACnet® interface TCP/IP
Remote advanced display (supplied loose)
Service display (supplied loose)
Remote control : customer drive contact input/output
Electric energy meter
Phase reversal protection
Power factor correction
Soft starter
Electrical box upgrade ventilation : 1 fan
Electrical box upgrade ventilation : 2 fans
Aluminum wires adaptor (supplied loose)
Rubber anti-vibration mounts type (supplied loose)
Wooden crate for long distance
NOTE: When it is possible options supplied loose should be included in a carton box inside the unit

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox GAH 020S and is the answer not in the manual?

Lennox GAH 020S Specifications

General IconGeneral
BrandLennox
ModelGAH 020S
CategoryChiller
LanguageEnglish

Related product manuals