icomfort™ Communicating Control System / Page 5
FEATURES
USER SETTINGS
USER DASHBOARD TABS
Programs Tab
Indoor Humidity
Alerts
HELP
HOME
Zones Tab (for future use)
Weather Tab - Displays outdoor temperature if
icomfort-enabled outdoor unit or optional outdoor
temperature sensor is enabled (set in user setup)
PROGRAMS
select
HELP
HOME
programs
press select to turn the program schedule ON or OFF
view/edit
(program ON)
(program OFF)
do you want to view or
edit the current program?
do you want to restore the
original energy saving program?
restore
January 26, 2010 12:00 AM
Program (Program On, Program Off)
Current Program (View or Edit)
Restore EnergyStar
®
Program (Conrm or Cancel)?
View Program
select
HELP
HOME
the following program settings have been saved
press a program to edit it
press NEW to create a program
(program ON)
(program OFF)
new
mon, tue,
wed, thu,
fri, sat,
sun
6:00
AM
8:00
AM
5:00
PM
10:00
PM
time
heat
cool
70
75
62
85
70
78
62
82
press to edit
fan auto auto auto auto
January 26, 2010 12:00 AM
Displays current program
Edit Program
next
HELP
HOME
select days to schedule
cancel
sat, sun
mon
all 7 days
set schedules for a group of days
all 7 days
mon - fri
tue wed thu fri sat sun
press next to edit the schedule for
set schedules for a specific day
OR
January 26, 2010 12:00 AM
Set schedule for a group of days (all 7 days, mon - fri,
sat - sun) or set schedule for each individual day
HELP
HOME
schedule for all 7 days
cancel back
6:00
AM
8:00
AM
5:00
PM
10:00
PM
time
70 62 70
62
78 85 78 62
heat
temp
cool
temp
fan
press and hold a time
button to turn an
individual setting on/off
auto auto auto auto
January 26, 2010 12:00 AM
Set time of day, heat temp., cool temp. and fan
settings for days selected (four events per day)
Skip an event if desired
Restore EnergyStar
®
Program
Restores program to EnergyStar
®
default comfort
settings:
Setting Time Heat Temp. Cooling Temp.
Wake 6:00 am < 70°F > 78°F
*Day 8:00 am Setback 8° F Setup 7°F
Evening 6:00 pm < 70°F > 78°F
*Sleep 10:00 pm Setback 8°F Setup 4°F
*At least setback and setup temperatures.
HELP
Left side of screen displays various help screens
depending on which dashboard tab is selected rst
(Indoor Settings, Programs, Indoor Humidity, Alerts)
Clean Screen (30 second timer for cleaning screen
without affecting settings)
Use Preferences (see User Preferences section for
details)
HOME
Returns to home screen