Do you have a question about the Lennox INNOVA DHADC Series and is the answer not in the manual?
Details the self-supporting frame construction and materials used.
Illustrates various airflow configurations for DX and CW units.
Provides a visual overview and component labels for the DHADC DX unit.
Shows an example of the DHADR DX unit with labeled components.
Presents an example of the DHCDR CW unit with key components identified.
Details the configuration digits for DX units, including version, airflow, and fan types.
Explains configuration digits for CW units, covering version, airflow, and fan types.
Discusses compressors, finned coil heat exchangers, plate heat exchangers, and remote condensers.
Lists refrigerant circuit components and details refrigerant pipe characteristics for installation.
Covers main components like fans, hydraulic circuits, and humidity control systems.
Details air filters, humidifiers, plenum kits, fresh air kits, and base frames.
Covers the electrical panel, its components, and microprocessor control options.
Discusses application ranges, operating conditions, and compressor oil heaters.
Lists the operating limits for the units, including refrigerant, pressure, and temperature specifications.
Discusses refrigerant properties and the operation of expansion valves.
Describes the stand-by rotation function for up to 6 units managed by a master unit.
Details master/slave logic for controlled environments and stand-by rotation features.
Explains monitoring and control via a web browser using HiNet systems.
Lists protocols used by Lennox for BMS connectivity, including Carel, Modbus, Bacnet, etc.
Presents technical specifications for air-cooled DX units, including airflow, capacity, and dimensions.
Provides detailed technical data for DX units with a single compressor.
Lists technical specifications for DX units equipped with two compressors.
Contains technical data for water-cooled DX units, including various operating conditions.
Continues technical data for water-cooled DX units, detailing specifications for different models.
Presents technical specifications for chilled water CW units at different temperature ranges.
Continues technical data for chilled water CW units, covering airflow, dimensions, and weight.
Lists technical data for chilled water CW units DHCDR/DHCUR, including cooling capacities and dimensions.
Continues technical data for DHCDR/DHCUR units, detailing airflow, fan specifications, and weight.
Provides technical data for standard execution remote condensers of the SHVN series.
Lists technical data for SHVN remote condensers in standard execution, covering various models.
Presents technical data for low noise execution remote condensers of the SVHS series.
Details technical data for SHVS remote condensers in low noise execution.
Continues data for remote condensers, covering both standard and low noise execution for various series.
Lists technical specifications for SHLR/N and SHLN dry coolers in standard execution.
Presents data for SHLN and SHLR/S dry coolers, covering standard and low noise executions.
Details technical data for SHLS dry coolers in low noise execution, covering various models.
Details correction factors for cooling capacity, current, and power based on ambient conditions.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Shows overall dimensions for Direct Expansion and Chilled Water CW units.
Presents overall dimensions for various remote condenser models.
Presents overall dimensions for various remote condenser models.
Presents overall dimensions for various remote condenser models.
Presents overall dimensions for various remote condenser models.
Presents overall dimensions for various remote condenser models.
Illustrates the hydraulic circuit for chilled water units with component references.
Displays the refrigeration circuit diagram for DX units with one compressor and component labels.
Shows the refrigeration circuit diagram for DX units with two compressors, including optional features.