7.3.1. Complete FC to iSCSI conversion
If you previously had FC host ports and you converted to iSCSI, you might need to modify your
existing configuration to support iSCSI. The following procedure is only applicable if there is no
iSCSI HIC present.
About this task
This task applies only if you are converting a storage array that has already been in use.
This task does not apply if you are converting a new storage array that does not yet have hosts and
volumes defined. If you converted the host-port protocol of a new storage array, see
Cabling
procedures. Then, follow the instructions in the Linux express configuration, Windows express
configuration, or VMware express configuration to complete the setup for each protocol.
Steps
1.
Configure the switches.
You should configure the switches used to transport iSCSI traffic according to the vendor’s
recommendations for iSCSI. These recommendations might include both configuration
directives as well as code updates.
2.
From ThinkSystem System Manager, select Hardware › Configure iSCSI ports.
3.
Select the port settings.
You can set up your iSCSI network in many ways. Consult your network administrator for tips
on selecting the best configuration for your environment.
4.
Update the host definitions in ThinkSystem System Manager.
If you need instructions to add hosts or host clusters, refer to the online help
for ThinkSystem System Manager.
a.
Select Storage › Hosts.
b.
Select the host to which the port will be associated, and click View/Edit Settings.
The Host Settings dialog box appears.
c.
Click the Host Ports tab.
138