CMVPFB01A ii
Contents
5. Cyclic Data Access ............................................................................................................13
5.1 What is Cyclic Data? .............................................................................................
13
5.2 Mapping Cyclic Data .............................................................................................
13
5.2.1 Data OUT (Dout) Channels ........................................................................13
5.2.2 Data IN (Din) Channels .............................................................................14
5.3 Channel Data Size.................................................................................................15
5.4 Cyclic Data ...........................................................................................................
16
5.4.1 Overview ..................................................................................................
16
5.4.2 P44x = 1, SMV Control Word ....................................................................16
5.4.3 P44x = 2, Network Frequency Setpoint ....................................................17
5.4.4 P44x = 3, Lenze C135 Control Word .........................................................18
5.4.5 P44x = 4 or 7, Network Speed Setpoint ....................................................19
5.4.6 P44x = 5, Network PID Setpoint ...............................................................19
5.4.7 P44x = 6, Network Torque Setpoint ..........................................................19
5.4.8 P44x = 8, Network Digital I/O Control Word ..............................................20
5.4.9 P44x = 9, Network Analog I/O Control Value .............................................20
5.4.10 P46x = 1, SMV Status Word .....................................................................21
5.4.11 P46x = 2, Actual Frequency .....................................................................21
5.4.12 P46x = 3, Lenze C150 Status Word ..........................................................22
5.4.13 P46x = 4, Actual Speed in RPMs ..............................................................22
5.4.14 P46x = 5, Auxiliary Status ........................................................................23
5.4.15 P46x = 6, Drive RUN Status ......................................................................24
5.4.16 P46x = 7, Drive Fault Status .....................................................................24
5.4.17 P46x = 8, Digital I/O Status ......................................................................26
5.4.18 P46x = 9, Analog 0-10V Input ..................................................................26
5.4.19 P46x = 10, Analog 4-20mA Input .............................................................26
5.4.20 P46x = 11, Actual PID Setpoint ................................................................
26
5.4.21 P46x = 12, Actual PID Feedback ..............................................................
26

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze AC Tech SMVector PROFIBUS-DP and is the answer not in the manual?

Lenze AC Tech SMVector PROFIBUS-DP Specifications

General IconGeneral
BrandLenze AC Tech
ModelSMVector PROFIBUS-DP
CategoryControl Unit
LanguageEnglish

Related product manuals