Lenze
4-20
8200 motec/starttec en 12/03
Accessories
Current limiting modules
Order no. I
N
[A] m [kg]
E82ZJ004
1)
/current limiting module 20 0.13
EZN3A0150H024/mains choke/mains filter 24 8.2
1)
For DIN rail mounting to EN50022 35 x 7.5 and 35 x 15
Technical data
Order no. Figure a [mm] b [mm] c [mm] d [mm] e [mm] m [mm] n [mm]
E82ZJ004
1)
/current limiting module A 43 57 50 86 91 70
EZN3A0150H024/mains choke/mains filter B 180 120 136 67 192 7 12
1)
For DIN rail mounting to EN50022 35 x 7.5 and 35 x 15
Dimensions
8200 motec 1 motec 2 motec 3 motec 4 motec 5 motec 6 motec Current limiting
measures
0.25 kW, 230 V
4 kW
Current limiting module
0.37 kW, 230 V Order no. E82ZJ004
0.55 kW, 400 V
0.75 kW, 400 V
4 kW 5.5 kW 7.5 kW 11 kW
Mains choke/filter
1.5 kW, 400 V Order no.
2.2 kW, 400 V EZN3A0150H024
1)
1)
E82ZJ004 also possible (use one module per phase)
Mains contactor [kW] with current limiting module when connecting...
A current limiting module reduces the current peak when
the 8200 motec(s) is (are) started up on the mains supply.
Assignment
a
b
c
e
d
m
Figure A
Figure B
Current limiting module E82ZJ004
Mains choke/filter EZN3A0150H024