MA 13.0001 DE-EN DE/EN 2.0
LED Colour State Note
State Green
on The control is correctly supplied by a 24 V control voltage, the drive is
ready for operation.
blinking Data is written on or read from the memory card.
off No voltage
Power Yellow
on The power section is enabled, the motor is supplied with voltage. The
drive works with the set control.
off The drive does not work, the output stage is inactive.
Error Red
off No fault
blinking Internal drive error
1)
After the cause of the error has been eliminated, you have to
acknowledge the error message:
z Either by using the parameterisation software, or via an edge at
DIN9 (controller enable).
z If no error is active anymore, the LED goes out.
Green
Yellow
Red
on z The drive is in the initialisation phase after the control voltage has
been switched on.
z A new firmware is being installed.
1)
Detailed description of the blink code: see Hardware Manual.
Note!
The light-emitting diode ”Error” constantly blinks if a fault is active:
ƒ It only displays one fault at a time.
ƒ If several faults are active at the same time, the fault that occured first is
displayed.