EasyManua.ls Logo

Lenze 930 Series

Lenze 930 Series
60 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
Feedback connection
Resolver at X7
4
53
MA 13.0001 DE-EN DE/EN 2.0
4.6 Feedback connection
4.6.1 Resolver at X7
Connection plan
+REF
-REF
+COS
+SIN
-SIN
-COS
+KTY
-KTY
1
2
3
4
5
6
7
8
9
X7
<15m
KTY
931E-005.cdr
Fig. 4 Resolver connection
Cores twisted in pairs
Assignment of the 9-pin Sub-D socket (X7) at the controller
Pin 1
2 3 4 5 6 7 8 9
Signal +REF -REF GND +COS -COS +SIN -SIN +KTY -KTY
0.5 mm
2
(AWG 20)
0.14 mm
2
(AWG 26)

Related product manuals