Troubleshooting and fault elimination
Display of operating data, diagnostics
Diagnostics
3
25
EDKVF93−05 EN 1.0
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0064 Utilization 0 {1 %} 150 Device utilisation I×t
l Read only
l Device utilisation during the last
180 s of operating time
l C0064 > 100 % releases warning
OC5
l C0064 >140 % limits the output
current to the rated controller
current
C0150 Status word
Bit00 — Bit08 Status code
Read only
Decimal status word for networking
via automation interface (AIF)
l Binary interpretation indicates the
bit states
Bit01 IMP Bit09 Status code
Bit02
— Bit10 Status code
Bit03
— Bit11 Status code
Bit04
— Bit12 Warning
Bit05
— Bit13 Message
Bit06
n = 0 Bit14 —
Bit07
CINH Bit15 —
3.1.2 Diagnostics
Description
Display codes for diagnostics
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0093 Drive ident
Controller identification
l Read only
0 Invalid Defective power section
1 None No power section
14
...
20
9335VC 400V
...
9383VC 400V
Display of the controller used
21
...
28
9334VC 500V
...
9383VC 500V
9321
...
9333
9321 VC
...
9333VC
C0099 S/W version
x.y
Software version
l Read only
x
y
Main version
Subversion