Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Transfering parameters to other standard devices
2
18
EDKVF93−05 EN 1.0
2.1.6 Transfering parameters to other standard devices
The keypad enables you to copy parameter settings from one standard device to another.
For this purpose use the "Load/Store" menu:
Danger!
During the transfer of the parameters from the keypad to the controller, the
control terminals may adopt undefined states!
For this reason it is imperative you disconnect connectors X5 and X6 from the
controller prior to the transfer. In this way you will ensure that the drive
controller is inhibited and all control terminals are in the defined "LOW" state.
Copying parameter sets from the standard device to the keypad
Note!
After the parameter sets are copied to the keypad XT (C0003 = 11), the
parameter set last loaded using C0002 is always activated.
So the actual parameters remain active also after copying:
ƒ Prior to copying, save the actual parameters in the parameter set and load
this parameter set into the drive controller using C0002.
Step Key
sequence
Action
1. Connect keypad to controller 1
2. Inhibit controller Terminal X5/28 = LOW
The drive coasts.
3. On the "Load/Store" menu select
C0003
On the "Load/Store" menu select code C0003 "PAR
SAVE" using the arrow keys.
4. Change to the parameter level
Display "0" and "READY"
5. Copy all parameter sets to the keypad The settings stored in the keypad are overwritten.
Set "11" "Save extern"
6. Start copying
The "RDY" status display goes off. "BUSY" is indicated
as parameter value.
When "BUSY" goes off after approx. one minute, all
parameter sets have been copied to the keypad. The
"RDY" status display illuminates.
7.
Change to the code level
A
Display of the operating level
B
Display of C0003 and "PAR SAVE"
8. Enable controller Terminal X5/28 = HIGH
9. Remove keypad from controller 1
efesotomasyon.com - Lenze