Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
2
15
EDKVF93−05 EN 1.0
Function keys
Note!
Key combinations with :
Press and keep it pressed, then press the second key in addition.
Key
Function
Menu level Code level Parameter level Operating level
Change to the
parameter level
Change to the operating
level
Change to the code
level
Load predefined
configurations in the
menu "Short setup"
1)
Accept parameters
when SHPRG or
SHPRG is displayed
Change between menu
items
Change of code number
Change of figure above
cursor
Quick change between
the menu items
Quick change of code
number
Quick change of figure
above cursor
Change between main menu, submenus and code
level
Cursor to the right
Cursor to the left
Cancel the function of key, the LED in the key is off
Inhibit controller, the LED in the key is lit
Reset the fault (TRIP
reset):
1. Remedy the cause of malfunction
2. Press
3. Press
1)
Only active for operation with standard devices of 8200 vector or 8200 motec series
2.1.4 Changing and saving parameters
Note!
Your settings have an effect on the current parameters in the main memory.
You must save your settings in a parameter set for not losing them when
switching the mains!
If you need only one parameter set, save your settings in parameter set 1, since
the parameter set 1 is automatically loaded after mains connection.
Step Key
sequence
Action
1. Select the menu Use the arrow keys to select the desired menu
2. Change to the code level Display of the first code in the menu
3. Select code or subcode Display of the current parameter value
4. Change to the parameter level
5. When SHPRG is displayed, inhibit the
controller
1)
The drive coasts
6. Change parameter
A Move cursor below the figure to be changed
B Change of figure
Quick change of figure
7. Accept the changed parameter