EasyManua.ls Logo

Lenze 9300 vector - Page 16

Lenze 9300 vector
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
2
16
EDKVF93−05 EN 1.0
ActionKey
sequence
Step
Display of SHPRG or SHPRG Confirm change to accept the parameter
Display "OK"
Display The parameter has been accepted immediately
8. Enable the controller, if required
1)
The drive runs again
9. Change to the code level
A Display of the operating level
B Display of the code with changed parameter
10. Change further parameters Restart the "loop" with step 1. or 3.
11. Save changed parameters
A Select the code C0003 "PAR SAVE" in the menu
"Load/Store"
B Change to the parameter level
Display "0" and "READY"
Select the parameter set in which
the parameters are to be saved
permanently
C Save as parameter set 1:
ð Set "1" "Save PS1"
Save as parameter set 2:
ð Set "2" "Save PS2"
Save as parameter set 3:
ð Set "3" "Save PS3"
Save as parameter set 4:
ð Set "4" "Save PS4"
D When "OK" is displayed, the settings are permanently
saved in the selected parameter set.
12.
Change to the code level
A Display of the operating level
B Display of C0003 "PAR SAVE"
13. Set parameters for another parameter
set
Restart the "loop" with step 1. or 3.
1)
The function of the key can be programmed:
C0469 = 1: Controller inhibit
C0469 = 2: Quick stop (Lenze setting)
efesotomasyon.com - Lenze

Other manuals for Lenze 9300 vector

Related product manuals