EasyManuals Logo

Lenze ECSEM Series Mounting Instructions

Lenze ECSEM Series
Go to English
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Electrical installation
Power terminals
Connection to the DC bus (+U
G
, −U
G
)
5
100
EDKCSEX064 DE/EN/FR 6.0
L3
N
L1
L2
Z1
K1
L1 L2
L3
PE
X21
+UG
+UG
+UG
-UG
-UG
-UG
PE
PE
PE
X22
X23
Off
On
+UG
BR1
BR0
M
3~
R
T1
T2
X6
...
J
2
6
K1
0
UV
W
PE
X24
BD1
BD2
X25
X7
"
"
+
"
"
+UG
+UG
-UG
-UG
PE
PE
X23
M
3~
R
J
2
6
0
UV
W
PE
X24
BD1
BD2
X25
X7
+
"
"
"
"
F4
F1...F3
"
"
ECSxS/P/M/A...
ECSxE...
ECSxS/P/M/A...
ECSXA011
Fig. 5−2 Power system: ECSxE power supply module with ECSxS/P/M/A axis modules
HF−shield termination by large−surface connection to functional earth (see
Mounting Instructions for ECSZS000X0B shield mounting kit)
Twisted cables
K1 Mains contactor
F1 ... F4 Fuse
Z1 Mains choke / mains filter, optional
J KTY thermal sensor of the motor
System cable for feedback˘

Table of Contents

Other manuals for Lenze ECSEM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze ECSEM Series and is the answer not in the manual?

Lenze ECSEM Series Specifications

General IconGeneral
BrandLenze
ModelECSEM Series
CategoryControl Unit
LanguageEnglish

Related product manuals