Diagnostics
Troubleshooting and fault elimination
Controller is inhibited
9
l
114
EDSMF2133IB EN 5.0
Select POW1 = 007E
hex
1
PIW1 =
xxxx xxxx x011 0001
bin
(ready to switch on)?
PIW1 =
xxxx xxxx x011 0111
bin
(operation enabled)?
No
Yes
Select POW1 = 007F
hex
OK
Enable controller
(terminal 28, C40)
For 821X/8200 vector/822X
setpoint selection with C0106 <> 0
via POW2
No
Yes
Setpoints or other control
signals can be selected