37
EDBSV571 EN 1.0
EN
Commissioning
4.5.8.3 Register 2003 - Drive State
Register 2003: Drive Status
Status Number Description
0 Fault Locked
1 Fault
2 Start Pending
3 Identification Not done
4 Stop - Inhibit
5 Stop
6 Switching On Sequence
7 Identification in Process
8 Running
9 Acceleration
10 Deceleration
11 Deceleration Override
12 DC Brake
13 Flying start
14 Slow Current Limit
15 Fast Current Limit
16 Sleep mode
4.5.8.4 Register 2010 - Digital Inputs
Register 2010: Digital Inputs
Status Number Description
0
1
2 Output Fault
3 Fast Current Limit State
4 TB1 ON
5
6 TB13A
7 TB13B
8 TB13C
9 TB14 Out State
10 Relay State
11 Charge Relay
12 Assertion level
13
14
15
16