EasyManua.ls Logo

Lenze I95AE222F

Lenze I95AE222F
184 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protecon of the machine/
system
Drives can reach dangerous overspeeds.
E. g. by seng high output frequencies in connecon with motors and machines not
suitable for this purpose.
The inverters do not provide protecon against such operang condions. For this
purpose, use addional components.
Switch contactors in the motor cable only if the controller is inhibited.
Switching while the inverter is enabled is only permissible if no monitoring funcons are
acvated.
Motor
If there is a short circuit of two power transistors, a residual movement of up to 180°/number
of pole pairs can occur at the motor! (e. g. 4-pole motor: residual movement max. 180°/2 =
90°).
NOTICE
High input voltage at the device.
Des
trucon of the device.
Observe maximum permissible input voltage.
Fuse device at the input against too high input voltage.
NOTICE
Short circuit at the device due to electr
ostac discharge.
Destrucon of the device.
The personnel must be free of electrostac charge prior to working on the device.
Safety ins
trucons
Residual hazards
103

Table of Contents

Related product manuals