Diagnoscs and f
ault eliminaon
LED status display
The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick
informaon about certain operang states.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
O O Supply voltage not available.
On On
Inialisaon in pr
ogress (inverter is being started.)
Blinks (1 Hz)
O
Safe torque o (S
TO) acve. The inverter has been inhibited by the integrated safety system.
Blinks (1 Hz) On
Inverter inhibited, error acv
e.
On
O
Inverter enabled.
Mot
or rotates according to the specied setpoint or quick stop is acve.
Both LEDs are blinking in a rapidly alt
ernang
mode
Firmware update acv
e.
Both LEDs are blinking in a very rapidly
s
ynchronous mode
"Visual tracking" funcon is acv
e.
Diagnoscs and f
ault eliminaon
LED status display
171